Photoplethysmography for bovine heat detection: the preliminary results
2020
In this study, we applied photoplethysmography (PPG) as an alternative, convenient, and affordable method for bovine heat detection. Heat detection is an essential part of effective herd reproduction management. Currently, there are many different heat detection techniques, but they can be ineffective or impractical to use. Since heat affects local vulvar blood circulation (resulting in swelling and erythema), photoplethysmography could represent an affordable alternative to detect this bovine phenomenon. In this study, we enrolled 20 animals in heat and other stages of the bovine reproduction cycle. We analyzed the PPG signal in terms of baseline (DC component), power, kurtosis, and erythe…
6‐1: Invited Paper: Measuring Health Parameters with Large‐Area Organic Photodetector Arrays
2021
Solution-processed organic photodetectors (OPDs) have witnessed great progress in the past few years. With silicon-like performance achieved, OPDs enable new medical imaging applications by offering cost-effective light detection over large area. Herein, we illustrate the compelling advantages of high spatial and temporal resolution OPD arrays for medical X-ray detectors and wearable pulse oximeters.
Challenges in automated estimation of capillary refill time in dogs
2018
Capillary refill time (CRT) is a part of the cardiorespiratory examination in dogs. Changes in CRT can reflect pathological conditions like shock or anemia. Visual CRT estimation has low repeatability; therefore, optical systems for automated estimation have recently appeared. Since existing systems are unsuitable for use in dogs, we designed a simple, small and portable device, which could be easily used at veterinary clinic. The device was preliminarily tested on several measurement sites in two dogs. Not all measurement sites were suitable for CRT measurements due to underlying tissue optical and mechanical properties. The CRT measurements were possible on the labial mucosa, above the st…
Photoplethysmography In Dogs And Cats: Selection Of Measurement Sites For Pet Monitor
2018
The PPG measurements of the study Cugmas et al, 2018. Notes.txt include all information about the dataset.
Biophotonics in veterinary medicine: the first steps toward clinical translation
2019
In this paper, we analyzed the current situation and the potential of biophotonics and biomedical optics in veterinary medicine. Promising optical techniques such as optical coherence tomography, pulse oximeter, and hyperspectral imaging have been clinically translated into human medicine. But even though human and small animal medicine share personalized and state-of-the-art approach, biophotonics remains rarely exploited in the canine and feline medicine. However, there are some biophotonics studies in veterinary oncology which addressed tumor diagnosis (skin and subcutaneous tumors), prognosis (lymphoma), and therapy (clear surgical margins). Visible and near-infrared spectroscopy served…
Clinical evaluation of automated capillary refill time estimation in dogs and cats
2019
In this study, we clinically evaluated a pulse oximeter-based device for automated capillary refill time (CRT) estimation in dogs and cats. CRT can reveal conditions like shock or anemia in dogs and cats. However, visual CRT estimation has low repeatability, and the available optical systems for automated estimation are not suitable for pets. We evaluated a custom-made portable CRT measuring device on various measurement sites of 12 dogs and 11 cats with parallel visual CRT estimation on the gum by treating veterinarian. The capillary refill was also recorded by a video camera for reference. The visual and video procedures were moderately correlated with the coefficient of 0.61; visual CRT …